Tycab Road Train - ADR 63 - Heavy Duty
Tycab Road Train – ADR 63 – Heavy Duty
- Application : Road Train Wiring – Road Train SPEC ADR 63
- MIN : 5mmsq (conductor area)
- MAX : 4ohms/km (electrical resistance)
- Conductor : OXYGEN FREE Plain Copper Wire to AS/NZS 1125
- Insulation : V90 PVC to AS/NZS 3808
- Core Colours : 1. White, 2. Yellow, 3. Brown, 4. Red, 5. Green, 6. Black, 7. Blue
- Sheath : 5V90 PVC to AS/NZS 3808
- Sheath Colour : Black
- Packs : 30, 100 metres – other packs by request
Code |
Nearest B&S |
No. of Cores |
Strand No. / Size |
Nominal Area (mm2) |
**AMP Rating at 30°C |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Electrical Resistance at 20°C (ohm/km) |
Nominal O.D. (mm) |
Mass (kg/100m) |
ATH565032 |
10 |
5 |
65/0.32 |
5.22 |
30 |
0.6 |
1.5 |
3.6 |
14.7 |
40 |
ATH765032 |
10 |
7 |
65/0.32 |
5.22 |
28 |
0.6 |
1.5 |
3.6 |
16.5 |
52.1 |
** AMP RATING: TO JASO D609 derating factors apply
Derating Factors for Ambient Temperatures °C |
Temperature |
30 |
40 |
50 |
60 |
70 |
Factor |
1 |
0.9 |
0.76 |
0.6 |
0.45 |