Tycab Road Train - ADR 63 - Heavy Duty | Tycab | ACP
19445
product-template-default,single,single-product,postid-19445,theme-bridge,wc-pac-hide-sale-flash,wc-pac-hide-add-to-cart,wc-pac-hide-price,wc-pac-hide-rating,woocommerce,woocommerce-page,woocommerce-no-js,ajax_fade,page_not_loaded,,hide_top_bar_on_mobile_header,columns-4,qode-theme-ver-17.0,qode-theme-bridge,disabled_footer_top,wpb-js-composer js-comp-ver-5.5.5,vc_responsive

Tycab Road Train - ADR 63 - Heavy Duty

Tycab 9.1. ATH_5CoreTycab 9.1. ATH_5Core

Tycab 9.1. ATH_5Core

http://acp-id.com/wp-content/uploads/2018/11/Tycab-9.2.-ATC_7Core.jpg

Tycab 9.1. ATH_5Core

Tycab Road Train – ADR 63 – Heavy Duty

  • Application       : Road Train Wiring – Road Train SPEC ADR 63
  • MIN                    : 5mmsq (conductor area)
  • MAX                   : 4ohms/km (electrical resistance)
  • Conductor         : OXYGEN FREE Plain Copper Wire to AS/NZS 1125
  • Insulation         : V90 PVC to AS/NZS 3808
  • Core Colours    : 1. White, 2. Yellow, 3. Brown, 4. Red, 5. Green, 6. Black, 7. Blue
  • Sheath               : 5V90 PVC to AS/NZS 3808
  • Sheath Colour : Black
  • Packs                 : 30, 100 metres – other packs by request
Code Nearest B&S No. of Cores Strand No. / Size Nominal Area (mm2) **AMP Rating at 30°C Insulation Thickness (mm) Sheath Thickness (mm) Electrical Resistance at 20°C (ohm/km) Nominal O.D. (mm) Mass (kg/100m)
ATH565032 10 5 65/0.32 5.22 30 0.6 1.5 3.6 14.7 40
ATH765032 10 7 65/0.32 5.22 28 0.6 1.5 3.6 16.5 52.1

** AMP RATING: TO JASO D609 derating factors apply

Derating Factors for Ambient Temperatures °C
Temperature 30 40 50 60 70
Factor 1 0.9 0.76 0.6 0.45