Tycab Double Insulated Cable | Tycab | ACP
19439
product-template-default,single,single-product,postid-19439,theme-bridge,wc-pac-hide-sale-flash,wc-pac-hide-add-to-cart,wc-pac-hide-price,wc-pac-hide-rating,woocommerce,woocommerce-page,woocommerce-no-js,ajax_fade,page_not_loaded,,hide_top_bar_on_mobile_header,columns-4,qode-theme-ver-17.0,qode-theme-bridge,disabled_footer_top,wpb-js-composer js-comp-ver-5.5.5,vc_responsive

Tycab Double Insulated Cable

ADCADC

ADC

Tycab Double Insulated Cable

  • Application      : Gas Conversions
  • Conductor        : OXYGEN FREE Plain Copper Wire to AS/NZS 1125
  • Insulation        : V90 PVC to AS/NZS 3808
  • Core Colour     : Red
  • Sheath               : 5V90 PVC to AS/NZS 3808
  • Sheath Colour : Black
  • Packs                 : 30, 100 metres – other packs by request
Code * MM Industry Equiv. Strand No. / Size Nominal Area (mm2) **AMP Rating at 30°C Insulation Thickness (mm) Sheath Thickness (mm) Electrical Resistance at 20°C (ohm/km) Nominal O.D. (mm) Mass (kg/100m)
ADC11603 3 14/0.32 1.13 20 0.4 0.8 16.5 3.8 2.75
ADC12603 4 23/0.32 1.84 28 0.4 0.8 10.2 4.2 3.7
ADC14103 5 36/0.32 2.9 37 0.4 0.8 6.4 4.6 4.62
ADC16503 6 57/0.32 4.59 48 0.6 0.8 4.1 5.7 7.1

* MM – is an industry term that identifies cable size and is not CONDUCTOR CROSS SECTION AREA
** AMP RATING: TO JASO D609 derating factors apply

Derating Factors for Bundling of Single Core Cables
No of Cables 1 2 3 4 5 6 to 7 8 to 10 11 to 12
Factor 1 0.8 0.7 0.6 0.55 0.5 0.45 0.4

 

Derating Factors for Ambient Temperatures °C
Temperature 30 40 50 60 70
Factor 1 0.9 0.76 0.6 0.45