Tycab Low Tension Primary Wiring | Tycab | ACP
19437
product-template-default,single,single-product,postid-19437,theme-bridge,wc-pac-hide-sale-flash,wc-pac-hide-add-to-cart,wc-pac-hide-price,wc-pac-hide-rating,woocommerce,woocommerce-page,woocommerce-no-js,ajax_fade,page_not_loaded,,hide_top_bar_on_mobile_header,columns-4,qode-theme-ver-17.0,qode-theme-bridge,disabled_footer_top,wpb-js-composer js-comp-ver-5.5.5,vc_responsive

Tycab Low Tension Primary Wiring

Tycab 1.1. ASC_Black descTycab 1.1. ASC_Black desc

ASC

http://acp-id.com/wp-content/uploads/2018/10/Tycab-1.2.-ASC_Blue.jpg

ASC

http://acp-id.com/wp-content/uploads/2018/10/Tycab-1.3.-ASC_Red.jpg

ASC

http://acp-id.com/wp-content/uploads/2018/10/Tycab-1.4.-ASC_Green.jpg

ASC

http://acp-id.com/wp-content/uploads/2018/10/Tycab-1.5.-ASC_Yellow.jpg

ASC

http://acp-id.com/wp-content/uploads/2018/10/Tycab-1.6.-ASC_White.jpg

ASC

http://acp-id.com/wp-content/uploads/2018/10/Tycab-1.7.-ASC_Grey.jpg

ASC

http://acp-id.com/wp-content/uploads/2018/10/Tycab-1.8.-ASC_Orange.jpg

ASC

http://acp-id.com/wp-content/uploads/2018/10/Tycab-1.9.-ASC_Violet.jpg

ASC

http://acp-id.com/wp-content/uploads/2018/10/Tycab-1.10.-ASC_Pink.jpg

ASC

http://acp-id.com/wp-content/uploads/2018/10/Tycab-1.11.-ASC_Brown.jpg

ASC

Tycab Low Tension Primary Wiring

  • Application: General Purpose Automotive Wiring
  • Conductor  : OXYGEN FREE Plain Copper Wire to AS/NZS 1125
  • Insulation   : V90 PVC to AS/NZS 3808
  • Colours        : Red, Blue, Green, White, Black, Brown, Violet, Orange, Grey, and the widest range of trace colours
  • Packs           : 30, 50, 100, 500, 1000 metres, bulk drum – depending on product type
Code * MM Industry Equiv. NZ Equiv. Strand No. / Size Nominal Area

(mm2)

**AMP Rating at 30°C Insulation Thickness

(mm)

Electrical Resistance at 20°C (ohm/km) Nominal O.D

(mm)

Mass (kg/100m)
ARM18032 2.5 148 8/0.32 0.64 13 0.4 29.9 2 0.9
ASC11603 3 150 14/0.32 1.13 20 0.4 16.5 2.2 1.4
ASC12603 4 152 23/0.32 1.84 28 0.4 10.1 2.6 2.1
ASC14103 5 154 36/0.32 2.9 37 0.4 6.4 3 3.3
ASC16503 6 156 57/0.32 4.59 48 0.6 4.1 4 5.3

* MM – is an industry term that identifies cable size and is not CONDUCTOR CROSS SECTION AREA
** AMP RATING: TO JASO D609 derating factors apply

 

Derating Factors for Bundling of Single Core Cables
No of Cables 1 2 3 4 5 6 to 7 8 to 10 11 to 12
Factor 1 0.8 0.7 0.6 0.55 0.5 0.45 0.4

 

Derating Factors for Ambient Temperatures °C
Temperature 30 40 50 60 70
Factor 1 0.9 0.76 0.6 0.45